Tender6 min
Writing the thatch roofing item in a tender document
With synthetic thatch, the difference between bids is almost never the price of the panel: it is what each bidder assumed the item covered. This note sets out how to write it so the bids are comparable.

The problem with an open item
When the tender says only “supply and install synthetic thatch roofing, m²”, each bidder fills the gaps their own way: one measures the plan projection and another the true sloped area; one includes battens and another leaves them in the structure item; one prices a certified panel and another an untested substitute.
The result is three bids with double-digit differences that reflect scope rather than efficiency. The fix is cheap: six extra lines in the specification.
The six figures that close the item
- Basis of measurement. State explicitly that the true sloped plane area is measured, not the plan projection.
- Required performance. Class A classification under ASTM E108, wind certification and UV exposure hours, with test documentation required as part of the bid.
- Exposure and installation. 22 cm exposure, 5 cm minimum side lap, seven fixings per panel and 18° minimum pitch.
- Scope of the battens. State whether they sit in this item or in the structure item. It is the ambiguity that distorts comparisons most.
- Terminations. Ridge, hip, valley, eave and flashings against hard construction, specifying the flashing material.
- Warranty and backing. Number of years, exactly what is covered and who issues it — manufacturer, distributor or installer.
What to require as a deliverable, not just as a price
Alongside price it is worth requiring three documents in the bid; they cost nothing later and prevent arguments on site:
- Fire test documentation for the system offered, with its scope stated.
- Panel data sheet, with declared dimensions and installed coverage.
- Warranty letter detailing what is covered and for how many years.
Unit of measure and closing quantities
The item is measured in m² of roof plane, but the order closes in 11 m² boxes and 370 m² pallets. It is worth stating in the tender that rounding surplus stays on site as the owner's replacement stock: it avoids the later argument over who owns the uninstalled boxes.
If you are putting the tender together, we can review the wording of the item and return the adjusted text along with the take-off on your roof plan.