Skip to content
Aerial view of synthetic thatch palapas beside a residential tower and a lagoon, Guanacaste

NIPA® synthetic thatch · Costa Rica

Synthetic thatch you can specify, not improvise.

Test documentation, construction details and quantities per m² for architects, contractors and hospitality. Class A fire rating, 260 km/h certified and a twenty-year warranty.

ASTM E108

Class A fire rating

260 km/h

Certified wind

0.186 m²

Coverage per panel

20 years

Documented warranty

Who we are

Techos.cr

We are the technical desk of palm.cr, the authorized distributor of NIPA® synthetic thatch in Costa Rica. This site exists for one purpose: so a professional can resolve a thatch roof without having to call anyone first.

Dimensions, coverage per panel, minimum pitch, fastening criteria, test documentation and completed work are all here. When you need closed quantities, a physical sample or pricing, the quote is handled on the main site.

View projects

Performance verified by third parties

Nothing we claim rests on our word. ASTM E108 Class A, 6,000 hours of UV exposure under ASTM G155 and wind certification at 260 km/h back every line of the data sheet.

Real design freedom

The panel installs over battens, with no sub-roof and a minimum pitch of 18°. That opens up hipped, conical and long-span planes that natural fibre forces you to limit.

Quantities without surprises

0.186 m² of installed coverage per panel, 11 m² per box and 10% waste: on your roof plan the take-off closes before tender, not during construction.

How we work with studios

From schematic design to the construction detail.

Specification and take-off

We work on your roof plan: we set exposure and laps, calculate panels, boxes and pallets, and return the quantity schedule in whatever format your cost plan uses.

Compliance and approvals

We supply the test documentation the plan reviewer, the fire department and the insurer ask for — with the exact scope of each test, so the submittal is not returned over an overstated claim.

Contemporary volume resolved with a thatch roof

Method

Four things we settle before the drawing is signed.

Geometry and pitch

We review planes, pitch and junctions. 18° is the working minimum, and it decides from the outset whether the roof resolves with hips or with clean planes.

Take-off and logistics

We close m², boxes, pallets and the delivery window against regional stock, with no import container to wait on for each phase.

Construction detail

Battens, 22 cm exposure, 5 cm side lap and seven fixings per panel. The finish is decided in the detail, not on site.

Documentation

Test reports, warranty letter and data sheet in the format your submittal needs, delivered the same day they are requested.

Completed work

Projects already standing.

Condominium social areas, beach clubs, residential towers and long-span ranchos across Guanacaste, Puntarenas and the Central Valley.

View projects
  • Amenities beside a crystal lagoon

    Residential tower

    Amenities beside a crystal lagoon

    Social-area palapas at the foot of a residential tower in Guanacaste, facing the lagoon beach.

  • Grill and bar palapa

    Residential tower

    Grill and bar palapa

    Covered social area looking onto the lagoon; a single-plane roof on a steel frame.

  • Palapa at the foot of the tower

    Residential tower

    Palapa at the foot of the tower

    NIPA® synthetic thatch roof against the tower's volume, with a deep eave.

  • Resort pool

    Hospitality

    Resort pool

    Roof over the pool area, with long planes and a deep eave towards the deck.

  • Social area

    Condominium

    Social area

    Condominium social rancho resolved as a hipped roof over timber structure.

  • Tower amenity

    Residential

    Tower amenity

    Amenity in a residential tower, with junctions against hard construction.

The numbers

What the specification rests on.

20years

of documented warranty against rot, panel deterioration and sudden colour loss

6,000hours

of UV exposure under ASTM G155, roughly twelve years of intense sun

260km/h

of certified wind, sized for hurricane season on the coast

The cost that never appears in the construction budget

Natural fibre is re-thatched every three to five years. Over twenty years that is four or five interventions, each with scaffolding, a closed area and organic waste. The honest comparison is never against one re-thatching: it is against all of them.

Completed long-span roof on a coastal project
Poolside rancho with a synthetic thatch roof

Technical desk

Need a figure for your submittal today?

Data sheet, test documentation, CAD details and a physical sample. We answer the same business day.

Technical desk

Specification team · palm.cr

Data sheet, test reports and construction details

Or message us on WhatsApp

+506 6214-0226

Get in touch

Specification questions

What comes up in plan review.

If you need a figure that is not here, write to us: if the test exists, we send it with its scope stated.

What is the minimum acceptable pitch?

18°. Below that angle water stops draining by gravity between laps and the system loses its waterproof condition. On long planes it is worth working between 22° and 30°, both for run-off and for how the sloped plane reads visually.

Does it install without a sub-roof or membrane?

Yes. The panel is fixed over battens and the lap resolves watertightness; the assembly is waterproof with no additional membrane. When the project calls for a ceiling or acoustic control, the sub-roof is added for comfort, not for watertightness.

How is material taken off from a roof plan?

Take the true sloped area of each plane — not the plan projection — divide by 0.186 m² of coverage per panel at 22 cm exposure and add 10% waste. The order closes in 11 m² boxes and 370 m² pallets.

What documentation goes into a permit submittal?

Panel data sheet, ASTM E108 Class A test documentation, wind certification and the warranty letter. Supplied on request, with the exact scope of each test stated so the submittal does not overstate it.

How much load does it add to the structure?

The panel is roughly 1.0 mm thick and works as a covering over battens, so its permanent load contribution is low compared with a clay or concrete tile. For structural calculation we send the weight per m² of the assembly with the batten layout your project defines.

Who supplies and who installs?

Both routes exist: supply to the contractor with on-site crew training, or full installation by a certified crew. Both are quoted at palm.cr.

Technical notes

Working material, not catalogue copy.

Take-off, details, fire code and design criteria. Published once or twice a month.

View all notes

Technical site

Take the palapa to drawings with data, not assumptions.

The data sheet, construction details and test documentation are delivered from here. Quoting, physical samples and pricing per m² are handled at palm.cr.